Describe with the aid of a diagram some form of a fuse which is used in the electric lighting circuit of a house. Give two reasons why a fuse must not be replaced by an ordinary copper wire.
Household Circuits · Question 62 of 73
Describe with the aid of a diagram some form of a fuse which is used in the electric lighting circuit of a house.
Solution:
Concept: A fuse is a safety device that works on the heating effect of current. It is a short piece of thin wire of a tin–lead alloy, of high resistance and low melting point (about 250 °C), joined in series in the live wire. When the current goes above its current rating, it heats up, melts and breaks the circuit.
Step 1 — Name the fuse.
The fuse used in the lighting circuit of a house is the rewireable (kit-kat) fuse, fitted in the live wire.
Step 2 — Describe its construction.
It has a porcelain base (socket), fixed on the board, with two metal terminals joined in the live wire, and a removable porcelain holder with two metal terminals. A short piece of fuse wire (tin–lead alloy) of suitable rating, 5 A for a lighting circuit, is stretched between the terminals of the holder. Porcelain is used because it is an insulator and does not burn.

Step 3 — Describe its working.
When the holder is pushed into the base, the fuse wire completes the live circuit. If the current becomes excessive, the wire melts and breaks the circuit. After the fault is removed, the holder is pulled out and a new wire of the same rating is fitted.
Step 4 — First reason against copper wire.
Copper has a high melting point (about 1080 °C, against about 250 °C for the fuse alloy), so it will not melt even when the current becomes dangerously high; the wiring may overheat and catch fire.

Step 5 — Second reason against copper wire.
Copper has a low resistance, and ordinary copper wire is thick, so it hardly heats up. It gives no protection to the appliances against overloading or a short circuit.
Therefore, the lighting circuit uses a rewireable porcelain fuse in the live wire, and a fuse must not be replaced by copper wire because copper has a high melting point and a low resistance.