A geyser is rated '1500 W, 250 V'. This geyser is connected to 250 V mains. Calculate :
(i) the current drawn,
(ii) the energy consumed in 50 hours, and
(iii) the cost of energy consumed at ₹ 4.20 per kWh.
Confirming your payment
Sign up now and get 250 free tokens.
Current Electricity · Question 160 of 160
A geyser is rated '1500 W, 250 V'. This geyser is connected to 250 V mains. Calculate :
(i) the current drawn,
(ii) the energy consumed in 50 hours, and
(iii) the cost of energy consumed at ₹ 4.20 per kWh.
Solution:
Concept: A rating such as '100 W, 220 V' means the appliance uses 100 W when connected to 220 V. From it, the resistance is R = V² ÷ P and the safe (normal working) current is I = P ÷ V. Energy in kWh is the power in kW multiplied by the time in hours, and the cost is the energy in kWh multiplied by the rate (price of one kWh).
Given: rating 1500 W, 250 V; V = 250 V; t = 50 h; rate ₹ 4.20 per kWh.
Step 1 — See that the geyser runs at its rating.
The mains is 250 V, the rated voltage, so the geyser takes its rated 1500 W.
(i)
Step 2 — Find the current drawn.
Since P = VI, the current is the power divided by the voltage.
(ii)
Step 3 — Find the energy in 50 hours.
We change 1500 W into 1.5 kW and multiply by the time in hours.
(iii)
Step 4 — Find the cost.
We multiply the energy in kWh by the rate per kWh.
So the cost is ₹ 315.
Watch out: Use kW (1.5), not W (1500), when finding the energy in kWh.
Therefore, (i) the current drawn is 6 A, (ii) the energy consumed in 50 hours is 75 kWh, and (iii) the cost is ₹ 315.