Draw a labelled diagram of a step up transformer and explain how does it work. State two characteristics of the primary coil as compared to its secondary coil.
Electro-magnetism · Question 126 of 136
Draw a labelled diagram of a step up transformer and explain how does it work.
Solution:
Concept: A transformer works on mutual induction and only with a.c.: the changing current in the primary coil sets up a changing flux in the soft iron core, and this changing flux, linked with the secondary coil, induces an e.m.f. in it. The e.m.f. per turn is the same in both coils, so Es ÷ Ep is equal to Ns ÷ Np (the turns ratio). In an ideal transformer the power in equals the power out, so the current changes the opposite way: Is ÷ Ip is equal to Np ÷ Ns.
Step 1 — Draw the diagram.
The labelled diagram shows the step-up transformer.

The primary of fewer turns of thick wire takes the a.c. input; the secondary of more turns of thin wire gives the output; both are wound on a closed laminated soft iron core.
Step 2 — Explain the working.
The a.c. supply is connected to the primary coil. The alternating current in it sets up a changing magnetic flux in the soft iron core, and the closed core carries this flux through the secondary coil. Since the flux linked with the secondary keeps changing, an alternating e.m.f. is induced in it by mutual induction. The output has the same frequency as the input.

The figure shows the changing flux going round the closed core and linking both coils.
Step 3 — Find the output voltage.
The same changing flux passes through every turn, so the e.m.f. per turn is the same in both coils, and the e.m.f.s are in the ratio of the turns.
In a step-up transformer Ns > Np, so Es > Ep: the voltage is increased. With negligible losses the power stays the same, so the current is decreased in the same ratio.
Step 4 — Compare the primary with the secondary.
Two characteristics of the primary coil of a step-up transformer are listed below.
1. It has fewer turns than the secondary.
2. It is made of thicker wire, because it carries the larger current (low voltage, large current), and thick wire keeps the I²R heating small.
Watch out: The transformer works only on a.c.; with a steady d.c. in the primary the flux would not change and no e.m.f. would be induced in the secondary.
Therefore, a step-up transformer works by mutual induction: the alternating current in the primary sets up a changing flux in the core, which induces a larger alternating e.m.f. in the secondary because it has more turns; compared with its secondary, the primary has fewer turns and thicker wire.