Competency-Based Questions (CBQ) · Question 40 of 40

Competency: Analysis & Evaluation A goods lift in a warehouse is run by a small logic controller.

Question 404 marksHard

Competency: Analysis & Evaluation

A goods lift in a warehouse is run by a small logic controller. Its sensors give D=1D = 1 when the lift door is fully closed, W=1W = 1 when the load is above the safe limit, and R=1R = 1 when a floor button has been pressed. The motor may run (M=1M = 1) only when the door is closed, the lift is not overloaded and a floor has been requested. A buzzer sounds (Z=1Z = 1) whenever the lift is overloaded, and also whenever a floor is requested while the door is still open. The controller's log below shows the sensor signals at six moments. (Hypothetical data.)

Momentt1t_1t2t_2t3t_3t4t_4t5t_5t6t_6
DD101010
WW001100
RR111000

(a) Write Boolean expressions for MM and ZZ.

(b) Find MM and ZZ at each of the six logged moments.

(c) To save a gate, a technician suggests using Z′=W+D‾Z' = W + \overline{D} for the buzzer instead. At which logged moment would Z′Z' differ from ZZ? Evaluate whether the change is acceptable.