Competency: Application A 400 W rooftop solar panel in Rajasthan has these values on its datasheet, measured at a cell…

Question 213 marksMedium

Competency: Application

A 400 W400\ \text{W} rooftop solar panel in Rajasthan has these values on its datasheet, measured at a cell temperature of 25 ∘C25\,^\circ\text{C} in sunlight of 1000 W m−21000\ \text{W m}^{-2}: open-circuit voltage 49.0 V49.0\ \text{V} and maximum power 400 W400\ \text{W}. The datasheet also gives the temperature coefficients: the open-circuit voltage falls by 0.27 %0.27\,\% of its 25 ∘C25\,^\circ\text{C} value, and the maximum power by 0.35 %0.35\,\% of its 25 ∘C25\,^\circ\text{C} value, for each 1 ∘C1\,^\circ\text{C} rise in cell temperature. On a summer afternoon, in the same sunlight, the cells reach 65 ∘C65\,^\circ\text{C}. (Hypothetical data.)

(a) Find the open-circuit voltage of the panel at 65 ∘C65\,^\circ\text{C}.

(b) Find the maximum power of the panel at 65 ∘C65\,^\circ\text{C}.

(c) Fitting the panel on a raised frame lets air flow behind it, and the cells then run at 50 ∘C50\,^\circ\text{C} instead. How much more power does the panel give, and how much more electrical energy over 5.05.0 hours of such sunlight?