Competency: Analysis & Evaluation When a new research reactor is loaded with fuel for the first time, the operators…

Question 394 marksHard

Competency: Analysis & Evaluation

When a new research reactor is loaded with fuel for the first time, the operators add the fuel bundles a few at a time, with the control rods held at a fixed setting, and watch a neutron detector. A small neutron source stays in the core throughout. With no fuel loaded, the detector reads C0=120C_0 = 120 counts per second. Once fuel is present, every neutron from the source starts a short chain of fissions that dies out, so the count rate rises to C=C01−kC = \dfrac{C_0}{1 - k}, where kk is the multiplication factor of the core. The readings are given below. (Hypothetical data.)

Number of fuel bundles loaded0088161624243232
Count rate CC (counts per second)120120150150200200300300600600

(a) Find the multiplication factor kk after 1616 bundles and after 3232 bundles.

(b) Find C0C\dfrac{C_0}{C} for each loading. Use the trend to predict the number of bundles at which the core would become critical.

(c) After 3232 bundles, an operator says, "The count rate is only five times what it was at the start, so we are still far from critical. Let us load the next 1010 bundles together to save time." Evaluate this plan.