Competency: Analysis & Evaluation
A mobile-phone charger contains a small transformer whose ring-shaped ferrite core is magnetised back and forth times a second. Ferrite is a ceramic magnetic material and a very poor conductor, so nearly all the heating in the core comes from hysteresis; take it all as hysteresis loss. To measure this loss, a technician fixes a tiny temperature sensor to the core, which is kept thermally insulated from the winding. The core has a volume of , a mass of and a specific heat capacity of . During the first , the heat lost to the surroundings is negligible. (Hypothetical data.)
| Time (s) | 0 | 25 | 50 | 75 | 100 |
|---|---|---|---|---|---|
| Core temperature () | 25.0 | 25.8 | 26.6 | 27.4 | 28.2 |
(a) Use the table to find the rate at which heat is produced in the core.
(b) Hence find the area of the core's hysteresis loop, that is, the energy lost per unit volume in each cycle.
(c) An engineer claims that if the switching rate is raised to times a second, with the core taken round the same loop, the core will heat up more slowly, because each cycle is shorter. Evaluate this claim, and find the new rate of temperature rise at the start.