Competency: Creativity Case study: A family moves into a new flat on the 220 V mains.

Question 405 marksHard

Competency: Creativity

Case study: A family moves into a new flat on the 220 V mains. The electrician has to share the appliances between a lighting circuit protected by a 5 A fuse and power circuits, each protected by a 15 A fuse and wired with a cable that can carry 15 A. He wants to arrange them so that no fuse blows when the family uses its appliances normally, and so that a fault in one power circuit does not leave the whole flat without supply. The appliances of the family are given below. (Hypothetical data.)

ApplianceNumberPower of each
LED lamp815 W
Ceiling fan375 W
Television1120 W
Refrigerator1150 W
Mixer-grinder1750 W
Iron11000 W
Geyser12000 W
Microwave oven11200 W

(a) Find the current of the lighting circuit when the lamps, fans, television and refrigerator are all on, and say whether the 5 A fuse is suitable.

(b) The mixer-grinder, iron, geyser and microwave oven could be used together. Show that one 15 A power circuit is not enough for them, and plan two power circuits so that each stays below 15 A with all its appliances on.