Competency: Creativity
Case study: A family moves into a new flat on the 220 V mains. The electrician has to share the appliances between a lighting circuit protected by a 5 A fuse and power circuits, each protected by a 15 A fuse and wired with a cable that can carry 15 A. He wants to arrange them so that no fuse blows when the family uses its appliances normally, and so that a fault in one power circuit does not leave the whole flat without supply. The appliances of the family are given below. (Hypothetical data.)
| Appliance | Number | Power of each |
|---|---|---|
| LED lamp | 8 | 15 W |
| Ceiling fan | 3 | 75 W |
| Television | 1 | 120 W |
| Refrigerator | 1 | 150 W |
| Mixer-grinder | 1 | 750 W |
| Iron | 1 | 1000 W |
| Geyser | 1 | 2000 W |
| Microwave oven | 1 | 1200 W |
(a) Find the current of the lighting circuit when the lamps, fans, television and refrigerator are all on, and say whether the 5 A fuse is suitable.
(b) The mixer-grinder, iron, geyser and microwave oven could be used together. Show that one 15 A power circuit is not enough for them, and plan two power circuits so that each stays below 15 A with all its appliances on.
(c) The family later buys a 2 kW air conditioner. Test whether it can be added to either of your power circuits, and state what the electrician should do.