Competency: Application
Case study: A small shop installs a flour mill (atta chakki) whose motor is rated 1100 W, 220 V. The mill has its own circuit, which is wired with a cable that can safely carry 15 A. An electrician measures the current of the motor with a clip-on ammeter, and records it in the table below. The shop has fuses of 5 A, 10 A, 15 A and 20 A. The electrician must choose the fuse for the live wire of the mill circuit. (Hypothetical data.)
| Condition of the motor | Current |
|---|---|
| Running steadily | 5.0 A |
| First 2 seconds after the switch is put on | 8.0 A |
(a) Show that the running current in the table agrees with the rating of the motor, and find how many times larger the starting current is.
(b) Which of the four fuses should the electrician fit? Give a reason for rejecting each of the other three.
(c) The fuse blows one day when the mill jams, and the shopkeeper wants to replace it with a piece of 20 A fuse wire so that it 'never blows again'. Judge this idea.