Question 102 marksMedium
Competency: Analysis & Application
The colours on the three wires of an old cable feeding a geyser have faded. An electrician labels the wires P, Q and R and, with the supply on, measures the potential difference between each pair. His readings are given below.
| Pair of wires | Potential difference |
|---|---|
| P and Q | 0 V |
| P and R | 220 V |
| Q and R | 220 V |
He also finds that wire Q is joined to the metal body of the geyser.
(a) Identify the live, neutral and earth wires. Give a reason.
(b) He replaces the cable with a new one that follows the new colour convention. State the colour of the wire that takes the place of each of P, Q and R, and name the wire in which the switch and the fuse of the geyser must be connected.