(a) For each reading, eV0=λhc−ϕ0. Subtracting the two equations removes ϕ0:
e(V01−V02)=hc(λ11−λ21)
300×10−91−400×10−91=1200×10−91=8.33×105 m−1
h=c(λ11−λ21)e(V01−V02)=3×108×8.33×1051.6×10−19×1.03=2.5×10141.648×10−19=6.59×10−34 J s
This is within 1% of the accepted value.
(b) At 300 nm, the photon energy is
λ1hc=300×10−96.59×10−34×3×108=6.59×10−19 J=4.12 eV
ϕ0=4.12−1.85=2.27 eV
(c) At 500 nm, the photon energy is 4.12×500300=2.47 eV, so the predicted stopping potential is
V0=2.47−2.27=0.20 V
The measured 0.16 V is 0.04 V lower. Plotted against frequency (ν=c/λ gives 1.0×1015, 7.5×1014 and 6.0×1014 Hz), the three points lie close to one straight line, as Einstein's equation requires. The small shortfall at 500 nm is within the usual error of such readings: near the threshold the current is tiny and the exact point where it vanishes is hard to judge.