Option (B) is correct.
Explanation: For the first eyepiece:
fo+fe=105,fo=20fe⇒fe=5 cm,fo=100 cm
The objective is unchanged, so the new eyepiece has fe′=110−100=10 cm:
m′=10100=10
A longer tube here means a weaker eyepiece, so the magnification drops. (A) scales m with the tube length (20×105110≈21), and (C) divides the new length by the old eyepiece (110/5=22).