(a) In normal adjustment, fo+fe=90 cm and fefo=17:
17fe+fe=90⇒fe=5 cm,fo=85 cm
(b) The objective still forms the image of the distant object at its focus, 85 cm from it. The eyepiece must form the final image at ve=−25 cm:
ue1=ve1−fe1=−251−51=−256⇒ue=−4.17 cm
Separation=85+4.17=89.2 cm
m=fefo(1+Dfe)=17(1+255)=20.4
The eyepiece moves 0.83 cm towards the objective. The magnifying power rises from 17 to 20.4, at the cost of a more tiring view.