(a) Graph (i) is a straight line through the origin, N2Φ2=MI1, so M is its slope:
M=5.0 A1.0 Wb=0.20 H
(b) ε2=−MdtdI1:
- 0 to 10 ms: dtdI1=0.0105=500 A s−1, so ε2=−100 V
- 10 ms to 15 ms: dtdI1=0.005−5=−1000 A s−1, so ε2=+200 V

The fall is twice as fast as the rise, so its emf is twice as large and of opposite sign.
(c)
q=R∣Δ(N2Φ2)∣=RMΔI1=100.20×5.0=0.10 C
(Check: I=100/10=10 A for 10 ms gives 0.10 C.)
(d) Zero. Over the whole 15 ms the current in coil 1 returns to zero, so the flux linked with coil 2 ends where it began. The charges of the two intervals (0.10 C one way, then 20 A for 5 ms = 0.10 C the other way) cancel.