Competency-Based Questions (CBQ) · Question 56 of 80
A wire carrying a current I = 200 A in the upward direction is placed in a uniform magnetic field B = 2 × 10^ -3 T…
Question 563 marksHard
A wire carrying a current I=200 A in the upward direction is placed in a uniform magnetic field B=2×10−3 T directed into the page, as shown in the figure.
A null point is a point where the net magnetic field is zero.
(a) On which side of the wire will a null point be located?
(b) On which side will it be located if the direction of the applied field is reversed? Calculate the perpendicular distance of the null point from the wire.
Concept used — null point of a straight wire in a uniform field
A long straight wire carrying a current I produces, at a distance r from it, a field
Bwire=2πrμ0I
whose lines are circles round the wire. The right-hand thumb rule gives their sense: thumb along the current, curled fingers along B. A null point is where this field is equal in size and opposite in direction to the applied uniform field, so that the two cancel.
Given:I=200 A, upward in the plane of the page; applied field B=2×10−3 T into the page; 2πμ0=2×10−7T m A−1.
Step 1 — Direction of the wire's own field. Take right =i^, up the page =j^ and out of the page =k^. The current is along +j^. The wire's field at a point is along I^×r^, where r^ points from the wire to the point:
left of the wire, r^=−i^: j^×(−i^)=+k^, out of the page;
right of the wire, r^=+i^: j^×i^=−k^, into the page.
Step 2 — (a) Applied field into the page. It can be cancelled only where the wire's field points out of the page, which is on the left of the wire.
Step 3 — (b) Applied field reversed (out of the page). Now the wire's field must point into the page, which happens on the right of the wire.
Step 4 — Distance of the null point. In either case the two magnitudes must be equal:
Answer: (a) on the left of the wire; (b) on the right of the wire. In both cases the null point is 2.0 cm from the wire.
Note: the null "point" is really a whole line of null points, parallel to the wire and 2.0 cm from it, because the wire's field is the same all along its length.