(a) At working temperature:
R800=PV2=10002202=48.4 Ω
(b)
R20=1+α(800−20)R800=1+(1.7×10−4)(780)48.4=1.13348.4≈42.7 Ω
(c) Area A=π(0.25×10−3)2=1.96×10−7 m2. Using the values at 20∘C:
l=ρR20A=1.0×10−6(42.7)(1.96×10−7)≈8.4 m

(d) At switch-on (cold): I=42.7220≈5.2 A. When hot: I=48.4220≈4.5 A. The small switch-on surge (about 13%) reflects nichrome's small α.
(e) Nichrome has a high resistivity (about 60 times that of copper), so a practical length gives the needed resistance; a copper element would need to be about 500 m long for the same wire. It also has a small temperature coefficient, so its resistance and power stay steady, and it does not oxidise readily at red heat.