(i) T1=300 K, T2=330 K and k2/k1=1.6×10−3/2.0×10−4=8, so log8=3×0.3010=0.9030.
logk1k2=2.303REa(T1T2T2−T1)
0.9030=2.303×8.314Ea×300×33030
Ea=300.9030×19.147×99000=57060 J mol−1
The activation energy is 57.1 kJ mol⁻¹.
(ii) A 30 K rise is three steps of 10 K. If the rate doubles each time, the overall factor is 2×2×2=8, which is exactly the observed ratio k2/k1=8. So the average factor per 10 K is 2.
(iii) Now k/k1=8.0×10−4/2.0×10−4=4, and log4=0.6021:
3001−T1=Ea2.303R×0.6021=5706019.147×0.6021=2.02×10−4 K−1
T1=3.333×10−3−0.202×10−3=3.131×10−3 K−1⇒T=319.4 K
The Arrhenius equation gives 319.4 K (46.4 °C). The 10-degree rule (two doublings) would predict 320 K. The two agree closely but not exactly: the factor per 10 K is not constant, because equal steps in T are not equal steps in 1/T. The rule is only a rough guide.