(a) Order and rate of release
Test zero order (equal amounts in equal times):
30.0−25.2=25.2−20.4=20.4−15.6=4.8 mg every 4.0 h
Test first order (equal fractions in equal times):
30.025.2=0.840,25.220.4=0.810,20.415.6=0.765
The amount lost per interval is constant and the fraction left per interval is not, so the release is zero order:
k=4.0 h4.8 mg=1.20 mg h−1
The patch is designed this way: the drug has to pass through a rate-controlling membrane, so the skin receives a steady dose whatever amount is still in the reservoir.
(b) At 32 °C
[R]=[R]0−kt=0⇒t=1.2030.0=25.0 h
At 24 h: 30.0−1.20×24=1.2 mg is left. The 24-hour schedule keeps a small reserve, so the dose never stops before the next patch goes on.
(c) Skin at 40 °C
With T1=305 K and T2=313 K:
logk32k40=2.303×8.31450000(3051−3131)=2611×8.380×10−5=0.2188
k32k40=1.655⇒k40=1.655×1.20=1.99 mg h−1
The release is still zero order, so
t=1.9930.0=15.1 h
It is dangerous for two reasons. For the first 15 hours the patient receives about 66% more drug per hour than intended, which can be an overdose for a strong pain-killer. Then the patch is empty for about 9 hours before it is due to be changed, so the pain relief stops. The total amount is the same, but the dose rate is what the body responds to.