(i)
logk1k2=2.303REa(T1T2T2−T1)⇒log5=19.147Ea×300×32020
Ea=200.6990×19.147×96000=6.42×104 J mol−1
The activation energy is 64.2 kJ mol⁻¹.
(ii) From k=Ae−Ea/RT at 300 K:
RTEa=8.314×30064230=25.75
A=keEa/RT=1.2×10−3×e25.75=1.2×10−3×1.53×1011=1.8×108 s−1
The pre-exponential factor is 1.8×108 s−1.
(iii)
t1/2(300 K)=1.2×10−30.693=578 s,t1/2(320 K)=6.0×10−30.693=116 s
The half-lives are 578 s at 300 K and 116 s at 320 K.

(iv) From k=Ae−Ea/RT, the ratio of the new to the old rate constant is
kknew=AAnew×e−(Ea,new−Ea)/RT
Doubling A multiplies k by exactly 2 at every temperature, because A stands outside the exponential.
Lowering Ea by 5 kJ mol⁻¹ multiplies k by e5000/RT:
at 300 K:8.314×3005000=2.005⇒e2.005=7.42
at 600 K:8.314×6005000=1.002⇒e1.002=2.72
| change | factor at 300 K | factor at 600 K |
|---|
| A doubled | 2 | 2 |
| Ea lowered by 5 kJ mol⁻¹ | 7.42 | 2.72 |
At 300 K, k rises from 1.2×10−3 to 2.4×10−3 s−1 if A is doubled, but to 8.9×10−3 s−1 if Ea is lowered. Lowering Ea has the bigger effect at both temperatures, but its advantage shrinks as T rises (7.42 falls to 2.72, which is only just above 2). At high temperature RT is larger, so a fixed change in Ea is a smaller fraction of RT and changes the exponential factor less. This is why a catalyst, which lowers Ea, speeds up a reaction most dramatically at low temperatures.