A student dips a thermometer at , of heat capacity , into of water at in an insulated test tube (heat capacity of the water ; ignore the tube). Find the steady reading, and explain why it is not and why thermometers for small samples must have a small heat capacity.
Competency-Based Questions (CBQ) · Question 36 of 80
A student dips a thermometer at 25.0 ^ , of heat capacity 8.0 J K^ -1 , into 5.0 g of water at 60.0 ^ in an insulated…
Question 362 marksMedium
Heat flows from the water into the thermometer until both reach a common temperature ; then they are in thermal equilibrium and the reading is steady. Heat lost by the water equals heat gained by the thermometer:
The zeroth law guarantees only that the steady reading equals the temperature of the water after they have come to equilibrium, not the temperature the water had before the thermometer took heat from it. Here the water has cooled by almost . A thermometer with a heat capacity much smaller than that of the sample takes very little heat, so the sample's temperature hardly changes and the reading is close to its original value.