(a) The circuit is overloaded. Overloading is drawing more current through a circuit than the circuit was built to carry — here, four appliances' worth of current through wiring meant for less.
(b) Each appliance draws its own current, and every one of those currents has to come along the single cable from the wall socket. That one cable therefore carries the sum of all four.
Joule's law says the heat produced in a conductor is
H=I2Rt
The heat goes up with the square of the current, so the total is what hurts: doubling the current through that cable makes it produce four times as much heat. The cable is also thin, so its resistance R is not negligible. A large I through a not-small R, for twenty minutes of t, is why it is warm.
(c) A fuse is a short piece of wire of high resistance and low melting point, made of tin or a tin–copper alloy, and it is connected in series in the live wire so that the whole current of the circuit passes through it.
Both of those facts matter here:
- Being in series, the fuse carries exactly the same current as the overloaded cable — it feels the fault just as strongly.
- Having a higher resistance than the ordinary wiring, it produces more heat per second than the wiring does (H=I2Rt, with a larger R); and having a much lower melting point, it needs far less heat to give way.
So the fuse is deliberately the hottest and weakest point in the whole circuit. As the current climbs it reaches its melting point long before the extension cable reaches the temperature at which its insulation would burn. It melts, the circuit is broken, and the current stops. The fuse is designed to be the first thing to fail, so that nothing else has to be.