(a) Copper — its resistivity is 1.7×10−8 Ω m, the lowest of the three. The lower the resistivity, the better the conductor.
(b) Resistance depends on resistivity, length and cross-sectional area:
R=AρL
For the same R and the same L, the area must rise in proportion to the resistivity. So the aluminium cable has to be made thicker:
ACuAAl=ρCuρAl=1.72.8=1.65
Mass is area × length × density, and the lengths are equal, so:
mCumAl=1.65×8.962.70=1.65×0.301=0.50
The aluminium cable is about half the mass of the copper one, even though its cross-sectional area has to be about two-thirds larger.
This is the whole reason aluminium is used. Copper is the better conductor, but that is the wrong thing to compare. What matters for an overhead line is conductance per kilogram, because every kilogram has to be held up by the towers — and on that measure aluminium wins comfortably. It is also cheaper.
(c) Aluminium is a soft metal with low tensile strength. A cable made of aluminium alone would stretch and sag between the towers, and could snap under its own weight, under wind loading or under a coating of ice.
The steel core does the mechanical job — it takes the pulling force and holds the span — while the aluminium around it does the electrical job. Each metal is used for the property it is best at. (Cables of this kind are called ACSR: Aluminium Conductor, Steel Reinforced.)